On the issue of assessing the condition of the hydrogenerator rotor insulation using the thermal vision method

Authors

DOI:

https://doi.org/10.31649/1681-7893-2026-51-1-313-320

Keywords:

hydrogenerator rotor, winding insulation, high-temperature zone, thermal imaging method, mathematical model, device.

Abstract

This article addresses the pressing issue of reconstructing the thermal profile of the rotor pole windings of a hydro-generator whilst it is in operation. Given the design of the hydro-generator, it is difficult to determine the temperature of the rotor windings, which rotate during operation, using conventional methods.

This paper proposes an approach involving the installation of a row of infrared sensors along the rotor radius, with the output voltage of each sensor being recorded, which is proportional to the measured temperature. At any given moment, only one segment of the rotor winding surface falls within the field of view of the infrared sensors. As the rotor rotates, another part of the winding surface enters the sensors’ field of view. By scanning the entire surface of the rotor windings over the course of a full rotation, we obtain a thermal map of the entire surface of the hydro-generator’s rotor windings. In the event of a localised temperature rise at each pixel, as detected by the corresponding infrared sensor, it is possible to assess the overall thermal condition of the windings. Equally interesting is the task of identifying a single turn or several turns with an elevated temperature, caused by their heating due to deterioration or damage to the insulation. A mathematical model has been developed that allows for the mathematical representation of a single winding turn with an elevated temperature, several turns, or several poles with an elevated temperature. Attention has also been paid to estimating the rate of temperature rise within a specific area of elevated temperature. A device structure is proposed that enables the identification of a single turn with an elevated temperature, allowing operational staff to make prompt decisions regarding the operational capability of the hydro generator. Provision is made for transmitting the temperature values of each pixel of the rotor windings to the operational staff’s computer for further analysis and data accumulation.

Author Biographies

V.V. Grabko, Vinnytsia National Technical University

Кандидат технічних наук, доцент кафедри комп’ютеризованих електромеханічних систем і комплексів

V.S. Oshchepkov, Vinnytsia National Technical University

Аспірант кафедри комп’ютеризованих електромеханічних систем і комплексів

References

Kudrya S.O. Renewable energy sources. Monograph. Kyiv: Institute of Renewable Energy of the National Academy of Sciences of the Republic of Ukraine, 2020, 392 p.

Segeda М. S. (2015) Electrical networks and systems: a textbook, National university «Lvivska politechnika», 3rd edition revised and supplemented, Lviv: Lvivska politechnika, 540 p.

Biet M. Rotor faults diagnosis in synchronous generators using feature selection and nearest neighbors rule / M. Biet, A. Bijeire // IEEE Symposium on Diagnostics for Electrical Machines, Power Electronics and Drivers Conf., 2011, pp. 300–306.

Neti P. Stator inter-turn fault detection of synchronous machines using field current and rotor search-coil voltage signature analysis / P. Neti, S. Nandi // IEEE Transactions on Industry Applications, 2009, Vol. 45, No. 3, pp. 911–920.

Condition monitoring of rotating electrical machines / P. Tavner, L. Ran, J. Penman, H. Sedding. London, United Kingdom: The Institution of Engineering and Technology, 2008, 282 p.

ISO 19283:2020 Condition monitoring and diagnostics of machines – Hydroelectric generating units. ISO copyright office: Geneva, Switzerland, 2020, 70 p.

Levitsky A. S., Zaitsev E. O., Bereznichenko V. O. Features of measuring radial runout of cylindrical surfaces of a hydraulic unit shaft, Hydropower industry of Ukraine, № 1-2, р. 39–44, 2019.

Glenn Mottershead, Stefano Bomben, Isidor Kerszenbaum, Geoff Klempner Handbook of Large Hydro Generators: Operation and Maintenance (IEEE Press Series on Power and Energy Systems), John Wiley & Sons, 2021, 672 р.

Bezprozvannykh G. V. Structural and technological solutions for improving the electrical characteristics of a high-voltage composite electrical insulation system of electric machines: monograph / G. V. Bezprozvannykh, O. V. Roginsky. Kharkiv: Madrid Printing House, 2023, 137 p.

Khvalin D. I. Basic requirements for modern diagnostics systems for powerful turbogenerators, Nuclear Energy and Environment, No. 1 (23), pp. 28-38, 2022.

Lagutin V. M., Lesko V. O., Teptya V. V. Relay protection of small and medium power generators: a textbook. Vinnytsia: VNTU, 104 p., 2017.

Reimert D. Protective Relaying for Power Generation Systems. CRC Press, 592 p., 2017.

Pat. 159826 UA, MPK G01K13/08. Device for thermal imaging diagnostics of the hydrogenerator rotor / V.V. Grabko, V.V. Grabko, V.S. Oshchepkov, V.L. Polishchuk (Ukraine). - No. u202405991; appl. 17.12.2024; publ. 09.07.2025, Bull. No. 28/2025.

Kukharchuk, V.V., Pavlov, S.V., Holodiuk, V.S., et al. Information conversion in measuring channels with optoelectronic sensors, Sensors , 2022, 22(1), 271

Downloads

Abstract views: 0

Published

2026-06-17

How to Cite

[1]
V. Grabko and V. Oshchepkov, “On the issue of assessing the condition of the hydrogenerator rotor insulation using the thermal vision method”, Опт-ел. інф-енерг. техн., vol. 51, no. 1, pp. 313–320, Jun. 2026.

Issue

Section

Optical And Optical-Electronic Sensors And Converters In Control And Environmental Monitoring Systems

Metrics

Downloads

Download data is not yet available.