Optoelectronic multispectral device to determine the state of the peripheral circulation

Authors

  • S. V. Pavlov Vinnytsia National Technical University
  • T. I. Kozlovska Vinnytsia National Technical University
  • V. P. Dumenko Vinnytsia State Pedagogical University. Kotsyubinsky
  • O. O. Sydoruk Vinnytsia National Technical University

Keywords:

photoplethysmography, peripheral circulation, optical electronic device, wavelength

Abstract

A brief overview of the photoplethysmographic method was given. The structural features of the skin and the principles of penetration of optical radiation into biological tissue depending on the wavelength were studied. Besides, the optimal wavelengths were determined to study the different layers of the skin. On the base of researches multispectral optoelectronic device to determine the state of the peripheral circulation was constructed.

Author Biographies

S. V. Pavlov, Vinnytsia National Technical University

Dr. Sc. , Professor

T. I. Kozlovska, Vinnytsia National Technical University

Ph.D., Senior Lecturer

V. P. Dumenko, Vinnytsia State Pedagogical University. Kotsyubinsky

PhD, senior lecturer

O. O. Sydoruk, Vinnytsia National Technical University

student

References

1. Оптико-електронні засоби діагностування периферичного кровообігу з підвищеною достовірністю / [Павлов С. В., Козловська Т. І., Василенко В. Б.] — Вінниця : ВНТУ, 2014. — 140 с.
2. Фізичні основи біомедичної оптики / [Павлов С. В., Кожем’яко В. П., Колісник П. Ф. КозловськаТ. І., Думенко В. П.] — Вінниця : ВНТУ, 2010. — 155 с.
3. Пушкарева А. Е. Методы математического моделирования в оптике биоткани. Учебное пособие. СПб : СПбГУ ИТМО, 2008. — 103 с.
4. J. Spigulis, L. Gailite, A. Lihachev, R. Erts. Simultaneous recording of skin blood pulsations at different vascular depths by multi-wavelength photoplethysmography, Appl. Opt., 46, 1754—1759 (2007).
5. Патент 99581 Україна, МПК А61В 5/02. Фотоплетизмограф / Павлов С. В. Козловська Т. І., Клапоущак А. Ю., Сидорук О. О.; заявник і патентовласник Вінн. нац. техн. унів-т.
№ u201500059; заявл. 05.01.2015; опубл. 10.06.2015, бюл. № 11/2015.
6. Prahl, S. A. Light transport in tissue: Ph.D. dissertation. / S.A. Prahl — Univ. Texas at Austin, 1988.
7. J. Allen, «Photoplethysmography and its application in clinical physiological measurement», Physiol. Meas., 28, R1-R39 (2007).
8. Pavlov S. Photoplethysmography in Integrated Evaluation of Collateral Circulation of Lower Extremities (354,70kb) / S. Pavlov, S. Sander, T. Kozlovska // Modern problems of radio engineering, telecommunications and computer science/ — TCSET’2014, February 25 — March 1, 2014, Lviv-Slavske, Ukraine.
9. Troy, T. L. Optical properties of human skin in the near infrared wavelength range of 1000 to 2200 nm / T. L. Troy, S. N. Thennadil // J. Biomed. Opt. — 2001. — Vol. 6. — 2. — P. 167—176.



REFERENCES
1. Optyko-elektroonni zacoby diahnostyvnnya pereferychnoho krovoobihu z pidvyshchenoyu dostvirnistyu / [Pavlov S. V., Kozlovska T. I., Vasylenko V. B.] — Vinnytsia : VNTU, 2014. — 140 с.
2. Fizychni osnovy biomedychnoyi optyky / [Pavlov S. V., Kozhemyko V. O., Kolisnyk P. F., Kozlovska T. I.,, Dumenko V. P.] — Vinnytsia : VNTU, 2010. — 155 с.
3. Pushkareva A. E. Metody matematycheskoho modelyrovanyya v optyke byotcany. Uchebnoe posobye. SPb: SPbHU YTMO, 2008. — 103 с.
4. J. Spigulis, L. Gailite, A. Lihachev, R. Erts. Simultaneous recording of skin blood pulsations at different vascular depths by multi-wavelength photoplethysmography, Appl. Opt., 46, 1754—1759 (2007).
5. Patent 99581 Ukraine, МПК А61В 5/02. Fotopletyzmohraf / Pavlov S. V., Kozlovska T. I., Klapoushchak A. Yu., Sydoruk O. O.; zayavnyk I patentovkasnyk Vinn. nats. tehhn. univ-t.
№ u201500059; zayavl. 05.01.2015; opubl. 10.06.2015, byul. № 11/2015.
6. Prahl, S. A. Light transport in tissue: Ph.D. dissertation. / S. A. Prahl — Univ. Texas at Austin, 1988.
7. J. Allen, «Photoplethysmography and its application in clinical physiological measurement», Physiol. Meas., 28, R1-R39 (2007).
8. Pavlov S. Photoplethysmography in Integrated Evaluation of Collateral Circulation of Lower Extremities (354,70kb) / S. Pavlov, S. Sander, T. Kozlovska // Modern problems of radio engineering, telecommunications and computer science/ — TCSET’2014, February 25 — March 1, 2014, Lviv-Slavske, Ukraine.
9. Troy, T. L. Optical properties of human skin in the near infrared wavelength range of 1000 to 2200 nm / T. L. Troy, S. N. Thennadil // J. Biomed. Opt. — 2001. — Vol. 6. — 2. — P. 167—176.

Downloads

Abstract views: 447

Published

2016-04-14

How to Cite

[1]
S. V. Pavlov, T. I. Kozlovska, V. P. Dumenko, and O. O. Sydoruk, “Optoelectronic multispectral device to determine the state of the peripheral circulation”, Опт-ел. інф-енерг. техн., vol. 30, no. 2, pp. 50–54, Apr. 2016.

Issue

Section

Biomedical Optical And Electronic Systems And Devices

Metrics

Downloads

Download data is not yet available.

Most read articles by the same author(s)

1 2 3 > >>